RNA Amplification
RampUp Kit

Catalog Numbers
RampUP* 10 assays RAMPUP10
RampUP Plus** 10 assays RAMP10PLUS
 
*The RampUP kit now contains cDNA Synthesis and labeling components which are required for gene expression analysis of senseRNA on Affymetrix 3’ Expression GeneChips and other arrays.

**If using Array 50, Array 350 or Array 900 to label poly(A)-tailed senseRNA (senseRNA modified with the Plus module), you will need to purchase the following high-concentration primers: Primer-30 pmol-Cy3, Alexa 546, Oyster 550 (cat. no. CMR960UA) Primer-30 pmol-Cy5, Alexa 647, Oyster 650 (cat. no. CMR960UB)

Order RampUP or RampUP Plus kits now

 
RampUP
The Best Kit for Affymetrix GeneChips!
RNA Amplification - RampUP
 
View RampUP compatibility with Affymetrix Platform (U133A)
 

RampUP and RampUP Plus are the ultimate RNA amplification kits for any RNA sample including difficult samples that are obtained from Formalin Fixed Paraffin Embedded tissue and Laser Capture Microscopy.

Genisphere’s newest RNA Amplification kits provide a two-round protocol that is as easy and accurate as one round. In this process, Sense-Strand Amplified RNA is produced through a proprietary Tandem RNA Polymerase Promoter technology referred to as TRPP.

TRPP technology works by using a tandem RNA polymerase promoter oligo that includes T7 and T3 RNA polymerase promoter sequences. As a result, the amplification product from round one T7 In Vitro Transcription has a built-in T3 RNA polymerase promoter sequence which is utilized in round two to avoid repeating the entire “promoter synthesis” process. The round two double stranded T3 RNA polymerase promoter is simply generated in two steps. The template strand is synthesized during the second round reverse transcription reaction and the non-template strand is hybridized to the cDNA template as a short oligonucleotide.

Very similar to our SenseAMP product, RampUP also results in no 3’bias. Amplification begins by synthesizing cDNA from the 3’ end of the message. The round one T7 amplification reaction that follows initiates at 3’ end of the cDNA (originally the 5’end of the RNA).

TRPP allows for RNA Amplification that is:

  Virtually Artifact-Free
  Highly Accurate
  Highly Reproducible
  High Throughput
 

senseRNA can be used for Affymetrix GeneChips, Glass Array labeling, qRT-PCR and many other RNA expression assays. RampUP Plus is recommended for laboratories using senseRNA in downstream dT priming applications. The “Plus” portion of RampUP Plus is for poly (A) tailing the senseRNA to ensure compatibility with any dT-based reverse transcription protocols.

See the easy 2-round RampUP and RampUP Plus process

 
Features and benefits:
 
  Simple Two-Round Amplification Protocol
    Because of the unique design of the RNA amplification process, using Tandem RNA Polymerase Promoters (TRPP), two rounds of amplification are as easy and accurate as one.
   
  Flexible Amplification Process
    Generates sense-strand RNA from all kinds of RNA samples, including partially degraded RNA and prokaryotic RNA.
     
  Artifact Free Amplification
    Amplified RNA contains virtually no non-specific amplification products.
     
  High Fidelity Amplification
    Amplified senseRNA accurately reflects the original sample without a 3’ bias.
     
  High Yield Amplification
    Offers greater than 105 fold amplification.
     
  Compatibility with any qRT-PCR, Microarray, or Affymetrix Application
    Optional PLUS module for poly(A) tailing ensures compatibility with dT-based reverse transcription protocols.
     
GeneChips is a trademark of Affymetrix, Inc.
  Top of Page
  Array Detection | RNA Amplification | About 3DNA | Signal Amplifiers
Literature | Tech Support | Current Promotions | Newsletters | Contact Us
Copyright © 2006 Genisphere. All rights reserved. 